Identifiler, Identifiler plus, PowerPlex 16), this result is frequently about 30 RFU. C. Re-analyze the evidence sample of interest, along with any associated negative controls at the new empirically determined threshold. In some instances you may wish to turn off the stutter filter. This is appropriate if a minor component is in the same peak. Download AmpFlSTR® Identifiler® Plus PCR Amplification Kit User`s Guide. 1. 2. The AmpFlSTR™ Identifiler ™ Allelic Ladder is used to genotype the analyzed samples. The alleles contained in the allelic ladder and the genotype of the AmpFlSTR™ Control DNA A are also listed in the table. Table 1 Identifiler™ Kit loci and alleles Locus designation Chromosome location Alleles included in AmpF™lSTR Identifiler.


Identifiler™ Plus kits. These improvements enhance the assay signal-to-noise ratio and simplify the interpretation of results. The primers used in the kits are: • For all loci except AMEL—The same primer sequences as the NGM SElect™ kit and the Identifiler™ Plus kit including SNP-specific primers for the vWA. The intensity and frequency of stutter peaks in the n-8 and n+4 positions were not reported in the user manual for standard amplification with Identifiler ; however, the n+4 stutter percentages noted herein are similar to the values calculated from profiles produced using a standard amplification protocol, that is, average + 3 SD values between. The reinterpretation of legacy data from the Identifiler® Plus PCR Amplification Kit will follow these procedures and reporting language with supplemental information specific to the Identifiler® Plus data noted in Appendix E. For interpretation of legacy STR amplification kit data using a statistical.


The AmpFlSTR® Identifiler® Plus Primer Set and Allelic Ladder contain primers that are labeled with light-sensitive dyes. Protect Protect the primers and allelic ladder from light; do not leave them exposed on the laboratory bench. Identifiler PCR Amplification Kit simultaneously amplifies 15 STR loci plus the Amelogenin gender-determining marker in a single, robust PCR. The widely accepted tetranucleotide loci co-amplified in the Identifiler Kit include the thirteen core STR loci as required for sample entry into CODIS (Combined DNA Index System): CSF1PO, D3S, D5S The reinterpretation of legacy data from the Identifiler® Plus PCR Amplification Kit will follow these procedures and reporting language with supplemental information specific to the Identifiler® Plus data noted in Appendix E. For interpretation of legacy STR amplification kit data using a statistical.

0コメント

  • 1000 / 1000